服務熱線
86-021-60719280 60719260
型(xing)號:SP-DDG-QZD
參考價格:¥330
更新時間:2022-07-07
訪問次數:1175
產品廠地:上海市
簡要描述:
全(quan)自(zi)動(dong)(dong)滴(di)定(ding)(ding)(ding)管(guan)(guan)(透明棕色(se)*)由上海書培實驗設備有限公司提供,規格(ge)(10ml,25ml,50ml )透明玻(bo)璃活塞全(quan)自(zi)動(dong)(dong)滴(di)定(ding)(ding)(ding)管(guan)(guan),透明四(si)氟(fu)活塞全(quan)自(zi)動(dong)(dong)滴(di)定(ding)(ding)(ding)管(guan)(guan),棕色(se)玻(bo)璃活塞全(quan)自(zi)動(dong)(dong)滴(di)定(ding)(ding)(ding)管(guan)(guan),棕色(se)四(si)氟(fu)活塞全(quan)自(zi)動(dong)(dong)滴(di)定(ding)(ding)(ding)管(guan)(guan)。提供實驗室整套玻(bo)璃器(qi)皿。
品牌 | shupeilab/書培 | 貨號 | SP-DDG-QZD |
---|---|---|---|
規格 | 10ml | 供貨周期 | 現貨 |
主要用途 | 做酸堿滴定實驗 | 應用領域 | 環保,化工,生物產業,制藥,綜合 |
全自動滴定管(透明棕色*)由上海書(shu)培實驗(yan)(yan)設備有限公(gong)司提(ti)供,規格(ge)(10ml,25ml,50ml )透明(ming)玻(bo)璃活(huo)塞(sai)全自動(dong)滴(di)(di)定(ding)管(guan),透明(ming)四氟(fu)活(huo)塞(sai)全自動(dong)滴(di)(di)定(ding)管(guan),棕色(se)玻(bo)璃活(huo)塞(sai)全自動(dong)滴(di)(di)定(ding)管(guan),棕色(se)四氟(fu)活(huo)塞(sai)全自動(dong)滴(di)(di)定(ding)管(guan)。提(ti)供實驗(yan)(yan)室整套(tao)玻(bo)璃器皿。
規格表:
產品名稱(cheng) | 規格 | 單價(元) | 品牌 |
全自動滴(di)定管(透明玻璃活塞) | 10ml | 330 | 書(shu)培 |
25ml | 350 | 書(shu)培 | |
50ml | 370 | 書培(pei) | |
全自動滴定管(透明四(si)氟活塞(sai)) | 10ml | 360 | 書培 |
25ml | 390 | 書(shu)培 | |
50ml | 430 | 書培 | |
全(quan)自動滴定(ding)管(棕色玻璃活塞(sai)) | 10ml | 370 | 書培 |
25ml | 390 | 書培 | |
50ml | 410 | 書培 | |
全自動滴定管(棕色四氟活塞) | 10ml | 400 | 書培 |
25ml | 430 | 書(shu)培(pei) | |
50ml | 470 | 書(shu)培(pei) |
產品介紹:
產品名稱:全自動滴定管(透明棕色*)
規(gui)格:10ml、25ml、50ml
種類:透明和棕(zong)色,玻璃活塞(sai)和四氟(fu)活塞(sai)
特點:參照自(zi)(zi)動滴(di)定管使用方法,但在充氣時不需用手指堵住氣管,自(zi)(zi)動浮芯子活(huo)塞就能自(zi)(zi)動控(kong)制。
用途:與自(zi)動滴(di)(di)定(ding)管相同。其(qi)特(te)點是(shi)貯(zhu)液(ye)瓶中液(ye)體(ti)壓(ya)到零點時(shi)(shi),多(duo)余(yu)的液(ye)體(ti)自(zi)動回流至貯(zhu)液(ye)瓶中,在(zai)滴(di)(di)定(ding)完后尚有余(yu)液(ye)在(zai)刻度管中,同樣(yang)可利用活塞(sai)放回貯(zhu)液(ye)瓶內,在(zai)充(chong)氣(qi)過多(duo)時(shi)(shi),可利用自(zi)動活塞(sai)放氣(qi),停止液(ye)面上升,重新(xin)打氣(qi)時(shi)(shi),自(zi)動活塞(sai)自(zi)動關閉(bi),較其(qi)它(ta)形式自(zi)動滴(di)(di)定(ding)管使用方便。
構造:
(1)全自動滴定管是由刻度滴定管與注液管平行焊接在一起,
注(zhu)液管(guan)(guan)(guan)(guan)中(zhong)制有(you)一圓球(qiu),起緩(huan)沖作(zuo)用。在刻度(du)量(liang)管(guan)(guan)(guan)(guan)上(shang)(shang)(shang)端有(you)一只向(xiang)上(shang)(shang)(shang)彎的(de)(de)液體出口(kou),作(zuo)調整零點用,其(qi)(qi)外層有(you)一球(qiu)與(yu)(yu)注(zhu)液管(guan)(guan)(guan)(guan)相(xiang)連,用以收(shou)集多(duo)余(yu)液體,并通過(guo)注(zhu)液管(guan)(guan)(guan)(guan)流回貯液瓶內(nei)。刻度(du)量(liang)管(guan)(guan)(guan)(guan)的(de)(de)下(xia)端焊有(you)兩根支(zhi)管(guan)(guan)(guan)(guan),向(xiang)外伸出成三角形與(yu)(yu)斜孔三路活塞,滴(di)液嘴(zui)相(xiang)連,其(qi)(qi)上(shang)(shang)(shang)面一根支(zhi)管(guan)(guan)(guan)(guan)是通過(guo)活塞、滴(di)液嘴(zui)把(ba)滴(di)定(ding)管(guan)(guan)(guan)(guan)的(de)(de)溶(rong)液滴(di)出。下(xia)面一根支(zhi)管(guan)(guan)(guan)(guan)用于滴(di)定(ding)完畢后,把(ba)滴(di)定(ding)管(guan)(guan)(guan)(guan)內(nei)的(de)(de)余(yu)液,通過(guo)活塞經此管(guan)(guan)(guan)(guan)流回至貯液瓶內(nei),刻度(du)量(liang)管(guan)(guan)(guan)(guan)與(yu)(yu)注(zhu)液管(guan)(guan)(guan)(guan)在兩根支(zhi)管(guan)(guan)(guan)(guan)之間(jian)合攏(long)成一玻璃管(guan)(guan)(guan)(guan),深入貯液瓶的(de)(de)底部。在磨砂口(kou)的(de)(de)上(shang)(shang)(shang)部有(you)一進(jin)氣管(guan)(guan)(guan)(guan),與(yu)(yu)雙(shuang)連球(qiu)連接,在進(jin)氣管(guan)(guan)(guan)(guan)的(de)(de)上(shang)(shang)(shang)部有(you)一自動(dong)浮芯(xin)子活塞,在充氣時自動(dong)活塞能自動(dong)關閉,充氣過(guo)多(duo)時可利(li)用自動(dong)浮芯(xin)子活塞放(fang)氣。
使用方法(fa):
1、在裝滴定液前,須將滴定管洗凈,使水自然瀝干(內壁應不掛水珠),先用少量標準溶液蕩洗三次,(每次約5~10ml),除去殘留在管壁和下端管尖內的水,以防裝入標準溶液被水稀釋。
2、標準溶液裝入滴定管應超過標線刻度零以上,這時滴定管*會有氣泡,必須排除,否則將造成體積誤差。如為酸式滴定管可轉動活塞,使溶液的急流逐去氣泡;如為堿式滴定管,則可將橡皮管彎曲向上,然后捏開玻珠,氣泡即可被溶液排除。
3、zui后,再調整溶液的液面至刻度零處,即可進行滴定。
注意事項 :
1、滴定管在裝滿標準溶液后,管外壁的溶液要擦干,以免流下或溶液揮發而使管內溶液降溫(在夏季影響尤大)。手持滴定管時,也要避免手心緊握裝有溶液部分的管壁,以免手溫高于室溫(尤其在冬季)而使溶液的體積膨脹,造成讀數誤差。
2、使用酸式滴定管時,應將滴定管固定在滴定管夾上,活塞柄向右,左手從中間向右伸出,拇指在管前,食指及中指在管后,三指平行地輕輕拿住活塞柄,無名指及小指向手心彎曲,食指及中指由下向上頂住活塞柄一端,拇指在上面配合動作。在轉動時,中指及食指不要伸直,應該微微彎曲,輕輕向左扣住,這樣既容易操作,又可防止把活塞頂出。
3、每次滴定須從刻度零開始,以使每次測定結果能抵消滴定管的刻度誤差。
4、在裝滿標準溶液后,滴定前“初讀"零點,應靜置1~2分鐘再讀一次,如液面讀數無改變,仍為零,才能滴定。滴定時不應太快,每秒鐘放出3~4滴為宜,更不應成液柱流下,尤其在接近計量點時,更應一滴一滴逐滴加入(在計量點前可適當加快些滴定)。滴定至終點后,須等1~2分鐘,使附著在內壁的標準溶液流下來以后再讀數,如果放出滴定液速度相當慢時,等半分鐘后讀數亦可,“終讀"也至少讀兩次。
5、滴定管讀數可垂直夾在滴定管架上或手持滴定管上端使自由地垂直讀取刻度,讀數時還應該注意眼睛的位置與液面處在同一水平面上,否則將會引起誤差。 (讀數應該在彎月面下緣zui低點,但遇標準溶液顏色太深,不能觀察下緣時,可以讀液面兩側zui高點,“初讀"與“終讀"應用同一標準。 )
6、滴定管有無色、棕色兩種,一般需避光的滴定液(如硝酸銀標準溶液、硫代硫酸鈉標準溶液等),需用棕色滴定管。